Advisory Details

February 14th, 2013

EMC AlphaStor Device Manager 0x75 Command Injection Remote Code Execution Vulnerability

ZDI-13-033
ZDI-CAN-1701

CVE ID CVE-2013-0928
CVSS SCORE 10.0, AV:N/AC:L/Au:N/C:C/I:C/A:C
AFFECTED VENDORS EMC
AFFECTED PRODUCTS AlphaStor
TREND MICRO CUSTOMER PROTECTION Trend Micro TippingPoint IPS customers are protected against this vulnerability by Digital Vaccine protection filter ID ['12677']. For further product information on the TippingPoint IPS: http://www.tippingpoint.com
VULNERABILITY DETAILS


This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of EMC AlphaStor for EMC Networker. Authentication is not required to exploit this vulnerability.

The specific flaw exists within Device Manager (rrobotd.exe) which listens by default on port 3000. When parsing the 0x75 command, the process does not properly filter the user supplied data allowing for arbitrary command injection and execution. A remote attacker can abuse this to execute remote code under the context of the SYSTEM user.

ADDITIONAL DETAILS EMC has issued an update to correct this vulnerability. More details can be found at:
http://www.securityfocus.com/archive/1/525362/30/0/threaded
DISCLOSURE TIMELINE
  • 2012-12-10 - Vulnerability reported to vendor
  • 2013-02-14 - Coordinated public release of advisory
CREDIT Aniway.Anyway@gmail.com