CVE ID | CVE-2014-8514 |
CVSS SCORE | 7.5, AV:N/AC:L/Au:N/C:P/I:P/A:P |
AFFECTED VENDORS |
Schneider Electric |
AFFECTED PRODUCTS |
ProClima |
TREND MICRO CUSTOMER PROTECTION | Trend Micro TippingPoint IPS customers are protected against this vulnerability by Digital Vaccine protection filter ID ['16734']. For further product information on the TippingPoint IPS: http://www.tippingpoint.com |
VULNERABILITY DETAILS |
The specific flaw exists within the MetaDraw ActiveX control's ObjLinks property. This property can be assigned an attacker-supplied memory address and the control will redirect execution flow to this given memory address. An attacker can exploit this condition to achieve code execution under the context of the browser process. |
ADDITIONAL DETAILS |
Schneider Electric has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 |
DISCLOSURE TIMELINE |
|
CREDIT | Ariele Caltabiano (kimiya) |