CVE ID | CVE-2018-7814 |
CVSS SCORE | 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Schneider Electric |
AFFECTED PRODUCTS |
GUIcon |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric GUIcon. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within parsing of a GD1 file. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the process. |
ADDITIONAL DETAILS |
Schneider Electric has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-18-347-01 |
DISCLOSURE TIMELINE |
|
CREDIT | mdm and rgod of 9SG Security Team |