Advisory Details

June 6th, 2018

GE MDS PulseNET Account Java RMI Incorrect Privilege Assignment Remote Code Execution Vulnerability

ZDI-18-551
ZDI-CAN-5591

CVE ID CVE-2018-10611
CVSS SCORE 6.5, AV:N/AC:L/Au:S/C:P/I:P/A:P
AFFECTED VENDORS GE
AFFECTED PRODUCTS MDS PulseNET
VULNERABILITY DETAILS


This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of GE MDS PulseNET. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.

The specific flaw exists within the configuration of the Remote Method Invocation interface. The interface is not sufficiently protected from low-privileged users. An attacker can leverage this vulnerability to execute code under the context of the service.

ADDITIONAL DETAILS GE has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02
DISCLOSURE TIMELINE
  • 2018-01-19 - Vulnerability reported to vendor
  • 2018-06-06 - Coordinated public release of advisory
  • 2018-06-06 - Advisory Updated
CREDIT rgod
BACK TO ADVISORIES