CVE ID | CVE-2018-10616 |
CVSS SCORE | 6.9, AV:L/AC:M/Au:N/C:C/I:C/A:C |
AFFECTED VENDORS |
ABB |
AFFECTED PRODUCTS |
Panel Builder 800 |
VULNERABILITY DETAILS |
The specific flaw exists within the handling of the IpAddress parameters of the ABB BeDVT OPC Driver. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code under the context of an administrator. |
ADDITIONAL DETAILS |
ABB has issued an update to correct this vulnerability. More details can be found at:
https://library.e.abb.com/public/30b77e0dc904475295401b66ec74cd3c/3BSE092089_A_en_SECURITY_-_Panel_Builder_800_Improper_input_validation_vulnerability.pdf?x-sign=OyK2T7i661JL8oQxBk+0/iWUV+hinpu8Nt6nvVmhw581vp4nkzkQbe1JSiJQPtp0 |
DISCLOSURE TIMELINE |
|
CREDIT | Michael DePlante - Leahy Center for Digital Investigation at Champlain College |