CVE ID | CVE-2021-32969 |
CVSS SCORE | 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Delta Industrial Automation |
AFFECTED PRODUCTS |
DIAScreen |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation DIAScreen. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XLS files. The issue results from the lack of proper validation of user-supplied data, which can result in a write before the start of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process. |
ADDITIONAL DETAILS |
Delta Industrial Automation has issued an update to correct this vulnerability. More details can be found at:
https://us-cert.cisa.gov/ics/advisories/icsa-21-208-05 |
DISCLOSURE TIMELINE |
|
CREDIT | kimiya |