CVE ID | CVE-2021-27399 |
CVSS SCORE | 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Siemens |
AFFECTED PRODUCTS |
Simcenter Femap |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of modfem files. The issue results from the lack of proper validation of user-supplied data, which can result in a write before the start of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process. |
ADDITIONAL DETAILS |
https://us-cert.cisa.gov/ics/advisories/icsa-21-159-12 |
DISCLOSURE TIMELINE |
|
CREDIT | Francis Provencher {PRL} |