CVE ID | CVE-2022-28663 |
CVSS SCORE | 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Siemens |
AFFECTED PRODUCTS |
Simcenter Femap |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of NEU files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. |
ADDITIONAL DETAILS |
Siemens has issued an update to correct this vulnerability. More details can be found at:
https://cert-portal.siemens.com/productcert/pdf/ssa-998762.pdf |
DISCLOSURE TIMELINE |
|
CREDIT | xina1i |