Advisory Details

August 15th, 2023

Schneider Electric EcoStruxure Operator Terminal Expert VXDZ File Parsing Code Injection Remote Code Execution Vulnerability

ZDI-23-1113
ZDI-CAN-17204

CVE ID CVE-2023-1049
CVSS SCORE 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
AFFECTED VENDORS Schneider Electric
AFFECTED PRODUCTS EcoStruxure Operator Terminal Expert
VULNERABILITY DETAILS

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Operator Terminal Expert. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.

The specific flaw exists within the processing of of VXDZ files while in simulation mode. When parsing name:value pairs in configuation data, the process does not properly validate a user-supplied string before executing it as code. An attacker can leverage this vulnerability to execute code in the context of the current user.

ADDITIONAL DETAILS

https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-01.pdf&_ga=2.140486835.1846662606.1686683693-1425362997.1686683693
https://www.cisa.gov/news-events/ics-advisories/icsa-23-180-02


DISCLOSURE TIMELINE
  • 2023-01-24 - Vulnerability reported to vendor
  • 2023-08-15 - Coordinated public release of advisory
  • 2023-09-20 - Advisory Updated
CREDIT Daan Keuper & Thijs Alkemade from Computest