CVE ID | CVE-2023-45601 |
CVSS SCORE | 7.8, AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Siemens |
AFFECTED PRODUCTS |
Tecnomatix Plant Simulation |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IGS files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. |
ADDITIONAL DETAILS |
Siemens has issued an update to correct this vulnerability. More details can be found at:
https://cert-portal.siemens.com/productcert/html/ssa-524778.html |
DISCLOSURE TIMELINE |
|
CREDIT | Anonymous |