CVE ID | CVE-2023-6407 |
CVSS SCORE | 5.3, AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H |
AFFECTED VENDORS |
Schneider Electric |
AFFECTED PRODUCTS |
APC Easy UPS Online |
VULNERABILITY DETAILS |
This vulnerability allows local attackers to create a denial-of-service condition on affected installations of Schneider Electric APC Easy UPS Online. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the deletePdfReportFile method. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. |
ADDITIONAL DETAILS |
Schneider Electric has issued an update to correct this vulnerability. More details can be found at:
https://www.cisa.gov/news-events/ics-advisories/icaa-23-346-01 |
DISCLOSURE TIMELINE |
|
CREDIT | 06fe5fd2bc53027c4a3b7e395af0b850e7b8a044 |