CVE ID | CVE-2024-7448 |
CVSS SCORE | 8.0, AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Magnet Forensics |
AFFECTED PRODUCTS |
AXIOM |
VULNERABILITY DETAILS |
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Magnet Forensics AXIOM. User interaction is required to exploit this vulnerability in that the target must acquire data from a malicious mobile device. The specific flaw exists within the Android device image acquisition functionality. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. |
ADDITIONAL DETAILS |
Magnet Forensics has issued an update to correct this vulnerability. More details can be found at:
https://docs.magnetforensics.com/docs/axiom/release_notes.html |
DISCLOSURE TIMELINE |
|
CREDIT | Andrew Clark IV |