Advisory Details

January 7th, 2015

Schneider Electric ProClima MetaDraw ArrangeObjects Remote Code Execution Vulnerability

ZDI-15-005
ZDI-CAN-2524

CVE ID CVE-2014-9188
CVSS SCORE 7.5, AV:N/AC:L/Au:N/C:P/I:P/A:P
AFFECTED VENDORS Schneider Electric
AFFECTED PRODUCTS ProClima
TREND MICRO CUSTOMER PROTECTION Trend Micro TippingPoint IPS customers are protected against this vulnerability by Digital Vaccine protection filter ID ['16827']. For further product information on the TippingPoint IPS: http://www.tippingpoint.com
VULNERABILITY DETAILS


This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Schneider Electric ProClima. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.

The specific flaw exists within the MetaDraw ActiveX control's ArrangeObjects method. The control dereferences an attacker-supplied memory address and redirects execution flow to the resulting address. An attacker can exploit this condition to achieve code execution under the context of the browser process.

ADDITIONAL DETAILS Schneider Electric has issued an update to correct this vulnerability. More details can be found at:
https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01
DISCLOSURE TIMELINE
  • 2014-10-15 - Vulnerability reported to vendor
  • 2015-01-07 - Coordinated public release of advisory
CREDIT Andrea Micalizzi (rgod)