CVE ID | CVE-2022-41657 |
CVSS SCORE | 7.1, AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H |
AFFECTED VENDORS |
Delta Electronics |
AFFECTED PRODUCTS |
InfraSuite Device Master |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to delete arbitrary files on affected installations of Delta Electronics InfraSuite Device Master. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the CtrlLayerNWCmd_FileOperation function. When parsing the fileName element, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to delete files in the context of an administrator. |
ADDITIONAL DETAILS |
Delta Electronics has issued an update to correct this vulnerability. More details can be found at:
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 |
DISCLOSURE TIMELINE |
|
CREDIT | Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative |