CVE ID | CVE-2023-1141 |
CVSS SCORE | 8.8, AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
AFFECTED VENDORS |
Delta Electronics |
AFFECTED PRODUCTS |
InfraSuite Device Master |
VULNERABILITY DETAILS |
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Electronics InfraSuite Device Master. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the ExeCommandInCommandLineMode function. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of an administrator. |
ADDITIONAL DETAILS |
Delta Electronics has issued an update to correct this vulnerability. More details can be found at:
https://www.cisa.gov/news-events/ics-advisories/icsa-23-080-02 |
DISCLOSURE TIMELINE |
|
CREDIT | Piotr Bazydlo (@chudypb) of Trend Micro Zero Day Initiative |